![]() Pc52842:~/hp_tools # /etc/init.d/hpsmhd start I installed the most recent versions of SMHP for the ML 350G4p (7.5.4-3), but starting it i get an error: And i don't see "SNMP" in "Data source", which i think is an indication that everything is fine if it would be available. I installed the same packages on the ML 350 G4p, but i get timeouts in SMHP and don't see the hardware in the browser. Pc53200:~/compaq/csp/linux # rpm -qa|grep -i ^hp On this system i have the following packages installed: I have a ML 350 G5 with SLES 10 and on it SMHP is running fine. I had SMHP running on two systems, but without knowing why they don't work anymore. I know these are old systems but they are still running fine. Or do I need to change some congirugation manually at HP SIM? (Critical message was not displayed even though the hardware has failed) Have anyone ever seen the same phenomenon? ![]() M元50 G5, SIM ver5.1.0, SartArray P400: OK (Critical: Accelerator Board Battery Failed (3040) message was displayed.) M元50pGen8, SIM ver7.1.0, SmartArray P420i: NG (Critical: Accelerator Board Battery Failed (3040) message was not displayed.) M元50Gen9, SIM ver7.6.0 SmartArray P440ar: NG (Critical: Accelerator Board Battery Failed (3040) message was not displayed.) M元50Gen9, SIM ver7.4.0, SmartArray P440ar: NG (Critical: Accelerator Board Battery Failed (3040) message was not displayed.) Update BIOS, iLO, Array Controller firmware to the latest version. "Critical: Accelerator Board Battery Failed (3040)" message still was not displayed. I tried the following methods to solve this problem on M元50 G9, but it was not resolved. Warning: Accelerator Board Status Change (3038)īut on M元50 G9 and M元50p G8, only "Accelerator Board Status Change (3038)" messages was displayed as "Warning". In the past the same occurred on M元50 G5 server, the following message was showed at events list correctly.Ĭritical: Accelerator Board Battery Failed (3040) I checked SSA and sure that Smart Storage Battery was broken on both M元50 G9 and M元50p G8. I have HP ACU(or SSA),SMH, SIM installed on each server.Ī while ago, I noticed that the Smart Storage Battery for Smart Array P440ar Controller on M元50 G9 was broken, but it seems that there was no critical message displayed in SIM event list.Īfter several days, I confirmed that exactly the same phenomenon occurred on M元50p G8. Now I am using several ProLiant Server which are M元50 G5, ML150 G6, M元50p G8, and M元50 G9. I have a question about the configurations of HP SIM. Assuming I pick AES on the iLO, where version of AES do I select in SIM? ![]() HPE provides for AES128/AES192/AES256 and DES/3DES whereas the iLO only provides for AES and DES.HPE SIM asks for a Contact Engine ID and Context Name whereas the iLO does not ask for this and only asks for Engine ID.In HPE SIM, for the SNMP v3 discovery credentials, there are more "options" and hence do no match what the iLO is asking for. However, I know little to nothing about SNMP v3 and have some questions:ġ) In the iLO, do I need to set any SNMP values if I am using SNMP v3? For example, do I need a Read community set? What about traps? How does SNMP v3 know where to send traps if I dont include this info in the SNMP section? Do I still need to provide a trap community and alert detination? Is this still clear text, or would SNMP v3 provide the encryption for the trap community?Ģ) Do I need both Authentication AND Privacy passphrase, or just one or the other? If not, what are the benefits of using both? I would like to move to SNMP v3, if possible. ![]() I am currently using SNMP with Agentless Management and HPE SIM. I think the problem is that i can't chosse anything in "data source". I reinstalled HPSMHP already (although it's not a windows box). ( ), but searching for it i found they are discontinued since ProLiant Gen 6. I found a posting saying i need to install wbem providers # Following entries were added by HPE Insight Management Agents at I found a lot of threads concnerning that problem, but mostly related to windows. SMHP is accessible on port 2381, but i just see "no items", and the "data source" is empty, nor wbem neither snmp. Installation seemed to work fine, i didn't get an error. I just installed the HP SMHP 7.6 on a SLES 11 SP4. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |